The Driller
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • NEWS
  • CLASSIFIEDS
  • EQUIPMENT
  • SAFETY
  • VIDEOS
  • EDUCATION
  • SOURCEBOOK
  • EVENTS
  • SUBMIT
  • ABOUT
  • SIGN UP
cart
facebook twitter linkedin youtube
  • NEWS
  • Water
  • Geothermal
  • Construction
  • Environmental
  • Mining
  • All Industry News
  • EQUIPMENT
  • Rigs & Heavy Equipment
  • Consumables
  • Pumps
  • Featured Products
  • VIDEOS
  • Newscast
  • Drill Talks
  • Ask Brock
  • Emerging Drillers
  • EDUCATION
  • Drilling Business Insights
  • Reference Desk
  • Sponsored Insights
  • EVENTS
  • Conferences & Demo Days
  • Newscast LIVE
  • SUBMIT
  • Drillers @Work
  • ABOUT
  • Contact
  • Advertise
The Driller
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
The Driller
  • NEWS
    • Water
    • Geothermal
    • Construction
    • Environmental
    • Mining
    • All Industry News
  • CLASSIFIEDS
  • EQUIPMENT
    • Rigs & Heavy Equipment
    • Consumables
    • Pumps
    • Featured Products
  • SAFETY
  • VIDEOS
    • Newscast
    • Drill Talks
    • Ask Brock
    • Emerging Drillers
  • EDUCATION
    • Drilling Business Insights
    • Reference Desk
    • Sponsored Insights
  • SOURCEBOOK
  • EVENTS
    • Conferences & Demo Days
    • Newscast LIVE
  • SUBMIT
    • Drillers @Work
  • ABOUT
    • Contact
    • Advertise
  • SIGN UP

Tech Topics: Sizing a Residential Water System - Part II: Pressure

By Bob Pelikan
July 1, 2007
There are three factors that go into determining the pressure required from a pump in a residential water system – lift pressure, household pressure and friction loss.



There are three factors that go into determining the pressure required from a pump in a residential water system:

  • Lift Pressure - pressure required to get the water from down in the well to the pressure tank;

  • Household Pressure - pressure required in the house to properly feed the fixtures;

  • Friction Loss - pressure required to overcome the friction in the pipes and fittings.

This month, we will examine the first two factors and tackle friction loss next time.

Lift Pressure

The first factor to consider is the pressure required to lift the water from the well to the pressure tank. The total lift required is the distance from the top of the water at the pumping level in the well to the highest fixture in the system, typically a second-story showerhead. We will let the pressure tank and pressure switch take care of the in-home lifting/pressure part as will be explained in a few moments. For now, let’s only consider getting the water from the well to the pressure tank.

The pumping level in the well is the level that the water drops to after the pump has been running long enough for the water level to stabilize. When the pump has been off long enough for the water level to rise to its natural height, this level is called static level.

The difference between static level and pumping level is called the drawdown, and it can be as little as a few inches in an under-utilized high-yield well to several hundred feet in a slow-producing well. The amount of lifting work the pump has to do is determined by the pumping level, not the static level, nor by the location of the pump in the well. The pumping level can change from season to season, and year to year, depending on ground water availability. Make sure you size your system to take into account the lowest probable pumping level.

Household Pressure

It is important to provide enough water pressure at the fixtures in the home to satisfy the comfort needs of the family. The Uniform Plumbing Code requires a minimum of 15 psi at each fixture. The easiest way to deal with the household pressure component of the total system pressure requirements is to choose a pressure tank operating range, which will provide at least 15 psi at the highest fixture. More on this in a moment.

Lift pressure is measured in terms of “feet of head,” i.e., the pumping level is 60 feet below the pressure tank. The household pressure is measured in terms of PSI (pounds per square inch) – the pressure tank operates through a range of 30 psi to 50 psi, for example. Just remember, you can use either term to express pressure, but you must be consistent in your formulas. And also remember, you can convert from one to the other as we explained last month by using the factors, 1 psi = 2.3 feet of head, or conversely 1 foot of head = 0.433 psi.

The Pressure Switch

The function of a pressure switch is to turn on the pump when the system pressure drops to the minimum set point and to turn it off when the system pressure reaches the maximum set point. The most com- monly used pressure switches have a 20-psi spread between the turn-on point and the turn-off point, and they are available in a number of on/off presets – 20/40, 30/50, 40/60, etc. With a 20/40 pressure switch, the pump will be turned on when the pressure drops to 20 psi, and turned off at 40 psi. With a 30/50 pressure switch, the pump will be turned on when the pressure drops to 30 psi, and off at 50 psi, and so on.

It is the pressure switch turn-on pressure (30 psi for a 30/50 switch) that determines the minimum system pressure at the highest fixture in the house. And it is the pressure switch turn-off pressure (50 psi) that is used to calculate the household pressure portion of your system pressure calculation.

Let’s say you have a 30/50 pressure switch. That means the minimum system pressure at the tank will be 30 psi. From the conversion formula above, for each foot in elevation above the tank, you loose 0.433 pounds. If you have a single-story house and the pressure tank is in the garage, 3 feet below the living level, that 7-foot high showerhead in the bathroom will be 10 feet above the pressure tank. Therefore, the pressure at this point will be 4.33 psi less than the pressure at the tank (10 feet x 0.433). The minimum system pressure at the showerhead will be 25.7 psi (30 – 4.33 = 25.7), assuming no friction loss in the pipes.

If you have a two-story house with a basement, that showerhead could be 25 feet above the pressure tank. In this case, the available pressure at the shower would be 30 – (25 x 0.433) = 19.2 psi, an amount sufficient to meet the minimum 15 psi requirement. However, if you were using a 20/40-pressure switch, you’d only have 9.2 psi at the upstairs showerhead, which does not meet the code, nor the customer’s satisfaction.

Calculating the Total Pressure Required

In our example, the static water level in the well is at 50 feet below the pressure tank, and the well draws down 10 feet, making the pumping level 60 feet. The household pressure requirement would be 50 psi because you are using a 30/50-pressure switch, which meets the minimum allowable pressure of 15 psi in the second-story showerhead. The total pressure required without friction loss, in terms of feet of head, would be

Lift pressure                                                                  60 ft.
Household pressure               + (50 psi X 2.31 =) 116 ft.
Total                                                                              176 ft.

Converting from feet of head back to PSI you get, 176 feet x 0.433 = 76 psi. (Mathematically speaking, it doesn’t matter which terms you use; just be consistent. You cannot add feet of head to PSI in an equation without converting to a common term, because all factors in the equation must be in the same terms. Once you’ve finished your math, you can convert back if it makes pump selection easier.)

Next month, we will continue this series on pump sizing with a look at pressure loss in the pipes. ’Til then ….
ND

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Bob is a regular contributor to The Driller. Contact bobpelikan@comcast.net to request a copy of The Pump Book, a compilation of Bob's columns for reference or training available for only $20.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • geotechnical drilling rig

    6 Onsite Phrases Environmental Drillers Hate

    Here are six phrases that highlight common frustrations...
    The Underground Network
    By: Jeff Garby
  • Wayne Nash

    Pipe Stuck? Common Causes and Solutions for Drillers

    If you have drilled for any length of time, sooner or...
    Markets
    By: Wayne Nash
  • submersible pumps, water well pumps

    Selecting and Sizing Submersible Pump Cable

    This article helps pump installers and servicers decide...
    Water Wells
    By: Bob Pelikan
You must login or register in order to post a comment.

Report Abusive Comment

Subscribe For Free!
  • eNewsletters
  • Online Registration
  • Subscription Customer Service
  • Manage My Preferences

The Driller Newscast, Episode 147: Global Geothermal Collaboration at NY-GEO 2025

The Driller Newscast, Episode 147: Global Geothermal Collaboration at NY-GEO 2025

The Driller Newscast: New York Geo Talks 2025 Conference with Hands-on Driller Education

The Driller Newscast: New York Geo Talks 2025 Conference with Hands-on Driller Education

The Driller Newscast: 21st Century Drillers | Part 1 DEMAND

The Driller Newscast: 21st Century Drillers | Part 1 DEMAND

The Driller Newscast: Coiled Tubing Drilling and the Future of Geothermal

The Driller Newscast: Coiled Tubing Drilling and the Future of Geothermal

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the The Driller audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of The Driller or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • demo of a DM450 drilling rig during a customer factory visit
    Sponsored byGeoprobe

    Built for You: Smarter Drill Rigs, Stronger Support, Bigger Opportunities

Popular Stories

MainPhotoTwoBrothers.jpg

Two Brothers' Journey Through the Drilling Industry

Tariffs

Tariffs Shake Up the Drilling Industry

AI and Drought Concerns

AI’s Growing Thirst for Water and Power

The Driller Classifieds

COMPRESSORS

EAST WEST MACHINERY & DRILLING IS BUYING AND SELLING AIR COMPRESSORS, AIR BOOSTERS, AIR ENDS & PARTS
Company: East West Machinery

DRILL RIGS

LOOKING FOR LATE MODEL TOPHEADS & DRILLTECH D25'S
Company: Spikes’s Rig Sales

DRILL RIG PARTS

MEETING DRILLERS NEEDS AROUND THE WORLD
Company: East West Machinery

ELEVATORS

SEMCO INC. PIPE ELEVATORS
Company: Semco Inc.

GROUTERS

GROUTING EQUIPMENT - GROUT PUMPS & GROUT HOSE REELS
Company: Geo-Loop Inc.

PUMP HOISTS

SEMCO INC. - BASIC PUMP HOISTS
Company: Semco Inc.

WELL PACKERS

LANSAS PRODUCTS - INFLATABLE WELL PACKERS
Company: Vanderlans Lansas Products

WELL SCREENS

WELL SCREENS & SLOTTED PIPE
Company: Alloy Screen Works

Products

Water Quality Engineering: Physical / Chemical Treatment Processes

Water Quality Engineering: Physical / Chemical Treatment Processes

By carefully explaining both the underlying theory and the underlying mathematics, this text enables readers to fully grasp the fundamentals of physical and chemical treatment processes for water and wastewater.

See More Products

Subscribe to The Driller Newscast

Related Articles

  • Tech Topics: Sizing a Residential Water System: Part 2 - Pressure

    See More
  • Tech Topics: Sizing a Residential Water System - Part 1: Flow

    See More
  • Tech Topics: Sizing a Residential Water System - Part 1: Flow

    See More

Related Products

See More Products
  • M:\General Shared\__AEC Store Katie Z\AEC Store\Images\ND\new site\water-and-wastewater-treatm.gif

    Water and Wastewater Treatment: A Guide for the Nonengineering Professional, Second Edition

  • managed.jpg

    Managed Pressure Drilling 1st Edition

  • M:\General Shared\__AEC Store Katie Z\AEC Store\Images\ND\new site\water-well-pumps.gif

    Audel Water Well Pumps and Systems Mini-Ref

See More Products

Related Directories

  • Rock-Tech International

    DTH Hammers (2" - 30"), Hammer Bits (2 3/4"- 42"), Std./Custom Hole Openers, PDC Bits, Drag Bits; Lost Bit head retrieval system; Drill Pipe; Tri-Cone TCI and Mill Tooth Rotary Bits.
×

Dig deeper into the drilling and water supply industry!

Build your knowledge with The Driller, covering the people, equipment and technologies across drilling markets.

SIGN UP NOW
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Classifieds
  • SIGN UP TODAY
    • Create Account
    • eNewsletters
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2025. All Rights Reserved BNP Media.

Design, CMS, Hosting & Web Development :: ePublishing

The Driller
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
The Driller
  • NEWS
    • Water
    • Geothermal
    • Construction
    • Environmental
    • Mining
    • All Industry News
  • CLASSIFIEDS
  • EQUIPMENT
    • Rigs & Heavy Equipment
    • Consumables
    • Pumps
    • Featured Products
  • SAFETY
  • VIDEOS
    • Newscast
    • Drill Talks
    • Ask Brock
    • Emerging Drillers
  • EDUCATION
    • Drilling Business Insights
    • Reference Desk
    • Sponsored Insights
  • SOURCEBOOK
  • EVENTS
    • Conferences & Demo Days
    • Newscast LIVE
  • SUBMIT
    • Drillers @Work
  • ABOUT
    • Contact
    • Advertise
  • SIGN UP